YBFBX5 High-Efficiency Flameproof and Dust-Protected Motor

The Shangli YBFBX5 series combines flameproof gas protection and dust ignition protection in a high-efficiency three-phase induction motor. The range covers 0.18–315 kW in frame sizes 80–355, with 2-, 4-, 6- and 8-pole models. Catalog Ex markings are Ex db IIC T4 Gb and Ex tb IIIC T130°C Db. Selection depends on the required output, hazardous-area classification and applicable certification.
Product Details

Product Overview

The Shangli YBFBX5 series is a high-efficiency three-phase induction    motor range combining flameproof protection for explosive gas    atmospheres with enclosure-based protection against combustible    dust ignition. It is designed to drive industrial equipment where    the motor specification must meet defined hazardous-area requirements.

The catalog range covers frame sizes 80–355 and rated outputs    from 0.18 to 315 kW, depending on the number of poles and motor    configuration. Available pole counts are 2, 4, 6 and 8.    Environmental variants can be specified for outdoor, tropical    and moderately corrosive operating conditions.

Key Features

  • Gas and dust protection:      catalog markings of Ex db IIC T4 Gb for explosive gas atmospheres      and Ex tb IIIC T130°C Db for combustible dust atmospheres.

  • Broad selection range:      multiple frame sizes, power ratings and pole counts to match      different industrial drive requirements.

  • High-efficiency design:      model-specific efficiency, current and power factor data      support motor selection and energy-use assessment.

  • Installation options:      foot-mounted, flange-mounted and combined mounting arrangements      are illustrated in the catalog, subject to frame and model availability.

  • Environmental variants:      options include outdoor, humid-tropical, outdoor tropical      and outdoor moderate-corrosion configurations.

Technical Specifications

ItemSpecification
SeriesYBFBX5
Motor typeThree-phase induction motor
Protection conceptsFlameproof enclosure for gas; protection by enclosure for dust
Frame sizes80–355
Rated output range0.18–315 kW, depending on pole count and model
Number of poles2, 4, 6 or 8
Gas protection markingEx db IIC T4 Gb
Dust protection markingEx tb IIIC T130°C Db
Performance table frequency50 Hz basis. Confirm the applicable ratings and performance          data when specifying a 60 Hz supply.
Catalog current reference380 V. Confirm the rated voltage, winding connection and          current for the selected motor.
EfficiencyRefer to the model-specific performance data.          Any required IE efficiency class must be confirmed separately.
Explosion-protection standards listedGB/T 3836.1-2021;          GB/T 3836.2-2021;          GB/T 3836.31-2021
Environmental optionsW, TH, WTH, WT and WF1

Specifications vary by model. The final motor nameplate,    applicable certificate and approved technical documentation    govern the supplied configuration.

Power Range by Pole Count

Number of PolesCatalog Output RangeSynchronous Speed at 50 Hz
20.75–315 kW3,000 rpm
40.55–315 kW1,500 rpm
60.37–250 kW1,000 rpm
80.18–200 kW750 rpm

Synchronous speed is a reference value, not the motor's rated    operating speed. Use the selected model's rated speed and torque    data when matching the motor to the driven equipment.

Understanding the Gas and Dust Protection Markings

Gas Protection: Ex db IIC T4 Gb

The gas marking identifies flameproof enclosure protection,    gas group IIC, temperature class T4 and equipment protection    level Gb. T4 corresponds to a maximum equipment surface temperature    of 135°C under the specified conditions.

Dust Protection: Ex tb IIIC T130°C Db

The dust marking identifies protection by enclosure, dust group    IIIC, a marked maximum surface temperature of 130°C and equipment    protection level Db. Dust selection must also account for the    material's ignition characteristics, dust layers and the installation    conditions.

Gas and dust markings describe different protection requirements.    A dual marking does not, by itself, establish suitability for    a simultaneous gas-and-dust hybrid mixture. Confirm the hazardous-area    classification, ambient conditions and certificate limitations    before selecting a motor.

Typical Application Sectors

The YBFBX5 series can be considered for industrial drives in the    following sectors, where the selected motor's protection marking    and certified operating conditions match the application:

  • Chemical and petrochemical processing:      equipment operating in classified explosive gas environments.

  • Food and agricultural processing:      equipment handling combustible materials such as flour,      cocoa and other organic dusts.

  • Wood and paper processing:      machinery in areas where combustible wood or paper dust may occur.

  • Textile processing:      equipment associated with combustible fibres, dust and flyings.

  • Plastics, resins and powder processing:      industrial drives requiring assessment for combustible dust exposure.

An industry name alone is not sufficient to establish suitability.    Provide the specific gas or dust characteristics and site    classification for technical review.

Environmental Configuration Options

SuffixConfiguration
WOutdoor version
THIndoor humid-tropical version
WTHOutdoor humid-tropical version
WTOutdoor tropical version
WF1Outdoor version for moderately corrosive environments

Specify the required environmental configuration when ordering.    These suffixes do not replace confirmation of ambient temperature,    humidity, corrosion exposure or hazardous-area approval requirements.

Mounting and Overall Dimensions
YBFBX5 motor mounting arrangements and dimensional reference drawing

The catalog illustrates IM B3, IM B5, IM B35, IM B14, IM B34    and IM V1 mounting arrangements. Availability depends on the    selected frame size and motor configuration; not every arrangement    is available across the full range.

Before finalizing an equipment layout or replacement installation,    request the model-specific dimensional drawing. Check the shaft    height, shaft extension, foot-hole spacing, flange dimensions,    terminal box position, cable entries and overall length.

Information Required for Selection and Quotation

To help our Huzhou team identify the appropriate YBFBX5 configuration,    please provide:

  • Required output in kW and operating speed or number of poles.

  • Supply voltage, frequency and starting or drive method.

  • Driven equipment, load characteristics and operating duty.

  • Gas or dust classification and the required protection marking.

  • Ambient temperature, altitude and indoor or outdoor conditions.

  • Mounting arrangement and any dimensional restrictions.

  • Destination country and required product approvals.

  • Quantity, delivery requirements and any special configuration.

For replacement enquiries, include a clear photograph of the    existing motor nameplate and its installation dimensions.    For variable-frequency operation, request confirmation of    suitability and the permitted operating range before ordering.