Request a Quote

Products

YBX4 Series High-Efficiency Flameproof Motor

The Shangli YBX4 series is a high-efficiency, totally enclosed fan-cooled three-phase induction motor for explosive-gas environments. Catalog outputs range from 0.18 to 315 kW, with IIB or IIC flameproof configurations available subject to model selection. The series features IP55 protection, IC411 cooling, Class F insulation and S1 continuous duty, with 50 Hz or 60 Hz versions and environmental options for different installation conditions.
Product Details

Product Overview

The Shangli YBX4 series is a high-efficiency, squirrel-cage three-phase induction motor developed for industrial explosive-gas environments. Its totally enclosed, fan-cooled construction combines flameproof protection with IC411 cooling, IP55 enclosure protection and Class F insulation.

The catalog specifies Grade 2 energy efficiency under GB 18613-2020. The series covers frame sizes 80 to 355 and outputs from 0.18 to 315 kW, depending on the selected pole configuration and model.

YBX4 motors are intended for continuous-duty equipment in industries such as petroleum, chemical processing, metallurgy and power generation. IIB and IIC flameproof configurations, different voltage ratings, and environmental variants allow selection to match the application's electrical and site requirements.

Key Features

  • High-efficiency design: The catalog specifies Grade 2 efficiency under GB 18613-2020, with performance data provided for individual models.
  • Flameproof configurations: The series lists Ex d IIB T4 Gb and Ex d IIC T4 Gb versions. The required configuration must be specified when ordering.
  • Totally enclosed, fan-cooled construction: IC411 cooling uses a shaft-driven external fan to remove heat from the motor enclosure.
  • Continuous-duty operation: S1 duty is specified for applications requiring continuous operation at the rated conditions.
  • IP55 protection and Class F insulation: Defined enclosure and insulation specifications support clear equipment-selection requirements.
  • Electrical configuration options: The catalog lists 380 V, 400 V, 660 V and 690 V options, including selected dual-voltage ratings, with 50 Hz or 60 Hz versions.
  • Installation and environmental options: IM B3 foot mounting is the basic arrangement. Other mounting arrangements and outdoor, tropical or corrosion-resistant versions can be reviewed for the application.

Technical Specifications

Item Specification
Series YBX4
Motor type Flameproof squirrel-cage three-phase induction motor
Construction Totally enclosed, fan-cooled (TEFC)
Catalog output range 0.18–315 kW, depending on model and pole configuration
Frame sizes 80–355
Pole configurations 2, 4, 6, 8 and 10 poles
Catalog voltage options 380 V, 660 V, 380/660 V, 400 V, 690 V and 400/690 V
Frequency options 50 Hz or 60 Hz, as specified for the supplied motor
Specified efficiency Grade 2 under GB 18613-2020
Insulation class Class F, thermal class 155
Cooling method IC411
Enclosure protection IP55
Duty S1 continuous duty
Basic mounting arrangement IM B3; other arrangements subject to confirmation
Catalog protection markings Ex d IIB T4 Gb or Ex d IIC T4 Gb, depending on configuration
Standard installation environment Indoor; environmental variants are listed separately

Specifications describe the series range. Not every combination of output, voltage, frequency, mounting arrangement and protection marking is necessarily available. Confirm the final selection against the quoted datasheet, nameplate and applicable certificate.

Power Range by Pole Configuration

Poles Catalog Output Range Synchronous Speed at 50 Hz
2 0.75–315 kW 3,000 rpm
4 0.55–315 kW 1,500 rpm
6 0.37–250 kW 1,000 rpm
8 0.18–200 kW 750 rpm
10 45–160 kW; 185 kW is also listed as a non-preferred specification 600 rpm

The catalog marks certain model and output combinations in parentheses as non-preferred specifications. Confirm these combinations before ordering. Actual rated shaft speed is lower than synchronous speed and varies by model.

Voltage, Frequency and Connection

The catalog lists single-voltage and dual-voltage configurations for different electrical supplies. Specify the operating voltage and frequency together when requesting a quotation.

For the basic 380 V series, the catalog specifies star (Y) connection for outputs up to and including 3 kW, and delta (Δ) connection above 3 kW. Always follow the supplied motor's nameplate and terminal connection diagram.

A 50 Hz option and a 60 Hz option do not automatically mean that each motor is dual-frequency rated. The published performance tables use 380 V current data and 50 Hz synchronous-speed groups; request the corresponding data for a different supply.

Special voltage requirements can be submitted for technical review.

Flameproof Protection

The YBX4 catalog lists two gas-protection configurations: Ex d IIB T4 Gb and Ex d IIC T4 Gb. These are alternative configurations, not combined approvals for every motor.

Specify the required gas group, temperature class, equipment protection level and hazardous-area classification with your enquiry. The current certificate and nameplate determine the approved marking and conditions of use.

Do not treat an IIB configuration as a substitute for an IIC requirement. Likewise, a gas-protection marking does not establish combustible-dust approval or underground coal-mining approval.

Where ATEX, IECEx or another destination-market approval is required, identify that requirement before quotation so that the relevant documentation can be checked.

Environmental Options

Code Catalog Description
Standard Indoor installation
W Outdoor version
WF1 Outdoor version for moderately corrosive environments
WF2 Outdoor version for strongly corrosive environments
F1 Indoor version for moderately corrosive environments
F2 Indoor version for strongly corrosive environments
TH Humid-tropical version
TA Dry-tropical version
THW Outdoor humid-tropical version
TAW Outdoor dry-tropical version

Describe the actual temperature, humidity, weather exposure and corrosive substances when selecting an environmental option. These codes do not imply resistance to every chemical or operating condition.

Model Designation Example

The catalog illustrates the designation YBX4-315L1-2-W:

  • YBX4: motor series designation
  • 315: shaft centre height of 315 mm
  • L: frame-length code
  • 1: core-length code
  • 2: two-pole configuration
  • W: outdoor environmental version

The model designation alone does not identify the complete electrical rating or explosion-protection approval. Check it together with the nameplate and technical datasheet.

Efficiency and Technical Documentation

The YBX4 catalog specifies Grade 2 energy efficiency under GB 18613-2020. For project approval or equipment comparison, request the rated efficiency and supporting documentation for the selected output, pole configuration, voltage and frequency.

If your project specifies an IEC efficiency class, include the required class and standard in the enquiry. An efficiency requirement should not be inferred solely from the numeral in the series name.

The catalog references standards covering motor ratings and performance, induction-motor testing, cooling, enclosure protection, mechanical vibration, noise, energy efficiency and flameproof construction. Applicable editions should be confirmed in the documentation for the supplied motor.

Applications and Selection

The catalog identifies petroleum, chemical processing, mining, metallurgy and power generation as application sectors. Suitability depends on the actual location and driven equipment, not the industry name alone.

Review the load torque, starting requirements, duty, mounting dimensions and site conditions alongside the required explosion-protection configuration. For inverter operation, frequent starting or unusual ambient conditions, request a specific technical review.

Request Technical Data and a Quote

Send our Huzhou team the following information to support motor selection and quotation:

  • Required output in kW and quantity
  • Supply voltage and frequency
  • Required rated speed or pole configuration
  • Driven equipment, starting method and duty requirements
  • Required IIB or IIC protection configuration
  • Hazardous-area classification and gas information
  • Mounting arrangement and dimensional constraints
  • Indoor or outdoor location and environmental conditions
  • Destination country and required certifications

For replacement enquiries, include a clear motor nameplate photograph and an installation drawing if available.

Send an Enquiry

Please share your requirements and contact details. Our team will get back to you.

WhatsApp: +8615523831294 +8615523831294 [email protected]

Home

Call

Back to Top

WhatsApp

Message