TYCP3 Permanent Magnet Motor with Integrated Drive

The Shangli TYCP3 series combines a permanent magnet synchronous motor with an integrated variable-frequency drive for pump and fluid-handling applications. The supplied catalog lists 1.5–30 kW models at 3,000 rpm and states Grade 1 motor efficiency under GB 30253-2024. Applications include multistage booster pumps, in-line pumps, HVAC circulation and industrial fluid systems.
Product Details

Product Overview

The Shangli TYCP3 series combines a permanent magnet synchronous motor (PMSM) with an integrated variable-frequency drive in a single motor-drive assembly. It is developed for pump and fluid-handling applications requiring adjustable speed and energy-efficient operation.

Permanent magnets provide the rotor magnetic field, while the integrated drive controls the motor's electrical supply and operating speed. The integrated arrangement brings the motor and its drive together at the equipment rather than treating them as separate standalone components.

The supplied catalog lists 1.5–30 kW models rated at 3,000 rpm and states that motor efficiency reaches Grade 1 under GB 30253-2024. Typical applications include multistage booster pumps, single-stage in-line pumps, HVAC circulation and industrial fluid systems.

Key Features

  • Integrated motor and drive: a permanent magnet synchronous motor combined with variable-frequency control in one assembly.
  • Variable-speed operation: motor speed can be matched to application requirements within the approved operating range.
  • High-efficiency motor design: Grade 1 efficiency under GB 30253-2024 is stated in the supplied product literature.
  • Pump-focused applications: intended for water supply, circulation and industrial fluid-handling equipment.
  • Extruded aluminium housing: identified by the YT designation in the catalog's model explanation.
  • Flange-mounting options: mounting drawings cover IM V18 / IM B14 and IM V1 / IM B5 arrangements for applicable models.

Technical Overview

Item Catalog Information
Series TYCP3
Motor technology Permanent magnet synchronous motor
Drive arrangement Integrated variable-frequency drive
Output range in the performance table 1.5–30 kW
Rated speed in the performance table 3,000 rpm
Pole count for the listed 3,000 rpm models 6 poles
Motor electrical frequency at the listed rated point 150 Hz
Voltage reference in the performance table 380 V; confirm the integrated drive's input supply specification separately
Listed full-load motor efficiency 88.6–95.3%, depending on model
Catalog efficiency declaration Grade 1 under GB 30253-2024
Additional speed version shown 1,500 rpm models appear in the dimensional table; their electrical performance data require separate confirmation.
Mounting arrangements illustrated IM V18 / IM B14 and IM V1 / IM B5, subject to model availability

The 150 Hz value is the motor electrical frequency associated with the listed six-pole, 3,000 rpm operating point. It is not the required mains input frequency. Confirm input voltage, phase count and frequency from the integrated drive's approved specification before connection.

Performance Data: 3,000 rpm Models

The following values are transcribed from the supplied catalog performance table. All entries below are six-pole models with a listed motor frequency of 150 Hz and a voltage reference of 380 V.

Model Output (kW) Full-Load Torque (N·m) Listed Efficiency (%) Listed Rated Current (A) Listed Weight (kg)
TYCP3-90YT-1.5-3000 1.54.7788.62.89.5
TYCP3-90YT-2.2-3000 2.27.0089.94.010.9
TYCP3-90YT-3-3000 39.5590.85.513.8
TYCP3-90YT-4-3000 412.7391.57.015.9
TYCP3-112YT-5.5-3000 5.517.5192.49.528.5
TYCP3-112YT-7.5-3000 7.523.8793.11332.5
TYCP3-112YT-11-3000 1135.0193.81945
TYCP3-160YT-15-3000 1547.7594.32565.5
TYCP3-160YT-18.5-3000 18.558.8994.73269.5
TYCP3-160YT-22-3000 2270.0394.93881
TYCP3-160YT-30-3000 3095.4995.352102

Model codes are reproduced as listed. Confirm the final designation and dimensions before ordering. The listed motor current must not be assumed to be the drive's mains input current. Confirm whether the stated weight includes all supplied drive components and accessories.

Applications

Multistage Booster Pumps

TYCP3 motors can be matched to multistage pumps used in building water-supply and pressure-boosting installations. Select the motor against the pump's required shaft power and operating speed.

Single-Stage In-Line Pumps

The series can be considered for in-line pump assemblies where the flange, shaft and mechanical loading are compatible with the selected motor.

HVAC Circulation

Variable-speed operation can support adjustment of circulation flow to system demand when used with suitable pump selection and system controls.

Industrial Fluid Systems

Applications include circulation and fluid-transfer equipment within the motor's approved operating conditions. Fluid compatibility and hydraulic performance depend on the pump, not on the motor alone.

Efficiency and System Performance

The catalog states Grade 1 motor efficiency under GB 30253-2024. The efficiency figures in the performance table should not be presented as the efficiency of the complete motor-drive-pump system.

Overall energy consumption also depends on drive losses, pump efficiency, pipework, operating flow, head and control strategy. Any energy-saving estimate should use the actual duty profile and a clearly defined comparison system.

Request model-specific test documentation where an efficiency requirement forms part of the project specification.

Integrated Drive and Control Requirements

The integrated drive controls the permanent magnet motor. Confirm the input power specification, permissible speed range and control interfaces for the selected assembly.

If the project requires constant-pressure control, external sensors, multi-pump coordination, remote communication or specific protective functions, state these requirements in the enquiry. Their availability must be confirmed rather than assumed from the integrated-drive construction.

Mounting and Pump Integration

The supplied drawings illustrate IM V18 / IM B14 and IM V1 / IM B5 mounting arrangements. Some flange options are not listed for all ratings. Use the drawing for the exact output and speed version.

  • Confirm flange diameter, spigot and fixing-hole arrangement.
  • Check shaft diameter, extension and key dimensions.
  • Confirm permissible pump thrust and other shaft loads.
  • Allow clearance for drive access, cabling and heat dissipation.
  • Check overall length against the pump and installation layout.

The 1,500 rpm and 3,000 rpm versions have separate dimensional entries. Do not substitute one version's drawing or performance data for the other.

Information Required for a Quotation

  • Required motor output and rated speed.
  • Pump type, flow, head and required shaft power.
  • Available input voltage, phase count and mains frequency.
  • Required speed range and operating duty.
  • Flange, shaft and pump-interface dimensions.
  • Required control functions, sensors and communication interfaces.
  • Ambient conditions and required enclosure protection.
  • Quantity, destination country and delivery requirements.

Contact our Huzhou team with the pump datasheet and installation requirements for selection support. Confirm whether the quotation covers the motor-drive assembly only or additional pump and control equipment.

Send an Enquiry

Please share your requirements and contact details. Our team will get back to you.

WhatsApp: +8615523831294 +8615523831294 [email protected]

Home

Call

Back to Top

WhatsApp

Message