YFBX4 Series High-Efficiency Dust-Protected Motor

The Shangli YFBX4 series is a high-efficiency three-phase induction motor for industrial environments with combustible dust. The catalog specifies dust ignition protection by enclosure, with the marking Ex tb IIIC T135°C Db. Outputs range from 0.18 to 315 kW across selected 2-, 4-, 6-, 8- and 10-pole models. Contact our team to confirm the electrical rating, installation requirements and certification for your application.
Product Details

Product Overview

The Shangli YFBX4 series is a high-efficiency three-phase    induction motor designed to drive industrial equipment    in environments where combustible dust may be present.    It uses dust ignition protection by enclosure, identified    by the protection marking Ex tb IIIC T135°C Db in the    product catalog.

The series covers a range of power ratings and pole    configurations for different equipment requirements.    Catalog outputs extend from 0.18 to 315 kW, with the    available output range depending on the selected    pole configuration and frame size.

Selection should take account of the electrical supply,    driven load, installation arrangement and hazardous-area    requirements. The supplied motor's nameplate and current    certification determine its approved conditions of use.

Key Features

  • Protection for combustible-dust environments:      Enclosure-based dust ignition protection, with the      catalog marking Ex tb IIIC T135°C Db.

  • High-efficiency design:      Model-specific efficiency values are provided in the      technical data for comparison and motor selection.

  • Multiple power and speed options:      The catalog includes 2-, 4-, 6-, 8- and 10-pole models      for different output and operating-speed requirements.

  • Three-phase induction motor construction:      Intended for industrial equipment drives requiring      a motor selected for the applicable dust hazard.

  • Detailed selection data:      Catalog tables include rated output, current, speed,      efficiency, power factor, starting characteristics      and other model-specific information.

Technical Specifications

Item Specification
Series YFBX4
Motor type High-efficiency three-phase induction motor
Intended environment Industrial combustible-dust atmospheres, subject to application assessment
Protection concept Dust ignition protection by enclosure, Ex tb
Catalog protection marking Ex tb IIIC T135°C Db
Catalog output range 0.18–315 kW, depending on model and pole configuration
Pole configurations 2, 4, 6, 8 and 10 poles
Frame sizes listed 80–355, depending on output and pole configuration
Catalog voltage reference 380 V for the published rated-current data
Frequency basis 50 Hz for the listed synchronous-speed groups
Efficiency Model-specific; confirm the required efficiency class when ordering
Standards referenced in the catalog GB/T 3836.1, GB/T 3836.31 and GB 18613-2020

For a different supply voltage or frequency, request    confirmation of the applicable motor rating and    performance data before ordering.

Power Range by Pole Configuration

Poles Catalog Output Range Synchronous Speed at 50 Hz
2 0.75–315 kW 3,000 rpm
4 0.55–315 kW 1,500 rpm
6 0.37–250 kW 1,000 rpm
8 0.18–200 kW 750 rpm
10 45–160 kW; a 185 kW specification is also listed as non-preferred 600 rpm

These are series ranges, not a statement that every    power and frame combination is available. The catalog    marks certain specifications in parentheses as    non-preferred; confirm these selections before ordering.    Actual rated shaft speed is lower than synchronous speed    and varies by model.

Understanding the Dust-Protection Marking

The catalog identifies the YFBX4 series with the marking    Ex tb IIIC T135°C Db.

Marking Meaning
Ex Explosion-protection marking
tb Dust ignition protection by enclosure, protection level “tb”
IIIC Dust group covering conductive dust
T135°C Marked maximum surface temperature of 135°C under the specified conditions
Db Equipment protection level for dust atmospheres

This dust-protection marking does not by itself establish    suitability for explosive gas atmospheres or confirm    ATEX or IECEx certification. Check the exact certificate,    nameplate and conditions of use for the motor being supplied.

Efficiency and Performance

The catalog references energy-efficiency grades 2 and 3    under GB 18613-2020 for the dust-motor range. The required    efficiency grade and any destination-market requirements    should be confirmed for the selected YFBX4 model rather    than inferred from the series name.

For equipment matching, review rated current, rated shaft    speed, starting torque, starting current and maximum    torque alongside output power. These characteristics    vary across the model range and affect starting and    operating performance.

Application and Selection Considerations

The YFBX4 series is intended for industrial drive    applications where a combustible-dust hazard has been    identified. Selection requires more than matching the    motor power to the equipment.

  • Confirm the hazardous-area classification, dust      characteristics and required protection marking.

  • Review dust ignition temperatures, possible dust-layer      accumulation and the permitted motor surface temperature.

  • Specify ambient temperature, altitude and installation      conditions.

  • Check load torque, starting requirements, duty cycle      and the required operating speed.

  • Confirm mounting dimensions, shaft dimensions and      the required enclosure IP rating.

  • If variable-speed operation is required, request a      specific motor-and-drive assessment. Do not assume      inverter-duty capability from the YFBX4 designation.

Request Technical Data and a Quote

Contact our Huzhou team with your equipment requirements.    To help us review the application and prepare a quotation,    please provide:

  • Required output in kW and order quantity

  • Supply voltage and frequency

  • Required speed or number of poles

  • Driven equipment, starting method and duty cycle

  • Mounting arrangement and dimensional requirements

  • Dust type and hazardous-area classification

  • Required protection marking and certification

  • Destination country and requested delivery date

For a replacement motor, include a clear nameplate    photograph and an installation drawing if available.    We can then review the electrical and mechanical    requirements before confirming the selection.